SYSTEM CONFIGURATION
10
SYSTEM CONFIGURATION
Two communication paths
SUB 1 SUB 2
COMMON 1 COMMON 2
One communication path
SUB 1 SUB 2
COMMON 1 COMMON 2
Communication paths on GH-BCX and
GH-VBX are identified as "COMMON 1"
and "COMMON 2". Each related
COMMON-SUB trunk has its own
communication path that can be used
within itself for communication between
Entrance and Resident. Crossover to the
other trunk is possible, but this will
occupy both talk and video paths.
Also Securitity Guard communication
occupies an entire system.
SYSTEM CONFIGURATION
Max. 8/COMMON line (3/Trunk)
1P
1Px2
COMMON 1
SUB 1BSUB 1A SUB 2A SUB 2B
1Px2
1P
1P
GH-BCX GH-VBX
GH-BC GH-BC
1Px2 1Px2
GH-MKGH-MK
1P
1P
1Px21Px2
1Px21Px2
GH-BC GH-VBC
1Px21Px2
1Px21Px2
GH-BC GH-VBC
Residential
Station
Max. 25
/Trunk
Max. 25
/Trunk
Residential
Station
No.2~5No.2~5
No.1 No.6 No.6No.1
Entrance Station
1P
1P
1P
Max. 2/COMMON line
Security Guard Station
Trunk line
STANDARD SYSTEM EXPANDED SYSTEM
GH-4Z
1P
GH-MKGH-MK
Security Guard Station : Max. 2
GH-1MD
GH-1MD
GH-1KD
+
GH-HS
GH-1AD
GH-1KD
GH-1KD
GH-BC GH-VBC
GH-1KD
GH-1KD GH-1KD GH-1KD
GH-1AD
1Px2
1Px2
1P
1P
1P
1Px2
1Px2
1Px2
1Px21Px2 1Px2 1Px2
1P
1P
1Px2
GH-4Z
Homerun Wiring with GH-4Z
Trunk line No.1
Station-to-station Wiring
Trunk line No.6
1Px2
1Px2
1Px2
1Px2
1Px2
1Px2
1Px2 1Px2
Doorbell Doorbell
Entrance Station : Max. 5 (3/Trunk)
1P
No.2~5
Note
*
On the same trunk line, do not have two
wiring methods mixed, Homerun wiring with
GH-4Z & Station-to-station wiring
1P
1P
GH-1KD
Max. 8/COMMON line (3/Trunk)
1P
1Px2
COMMON 2
COMMON 1 COMMON 2
1Px2
1P
1P
Entrance Station
GH-MK GH-MK
1P
1P
1P
1P
1P
Max. 2/COMMON line
Security Guard Station
Station-to-station Wiring
is not possible for GH-1MD
Residential Station
Max. 25/Trunk
Max. 4 stations (up to 2 monitor stations)/residence
For COMMON 1 For COMMON 2
<
COMMON 1 - SUB 1
><
COMMON 2 - SUB 2
>
4way video unction unit
Max. 6/Trunk
Residential Station
Max. 125/SUB trunk line
Residential Station
Max. 125/SUB trunk line
Residential
Stations
48
Entrance
Stations
5
Security Guard
Stations
2
Residential
Stations
500
Entrance
Stations
16
Security Guard
Stations
4
Wiring distance
GH-BCX to GH-BC
GH-VBX to GH-VBC
GH-BCX/VBX to Entrance Station
GH-BCX to farthest GH-1AD(Audio line)
GH-VBX to farthest Monitor (Video line) 1 Monitor/Resid.
GH-VBC to farthest Monitor (Video line) 2 Monitors/Resid.
Accumulated total per COMMON
Accumulated total per SUB
Wiring distance
GH-BC to Distribution point
Distribution point to Entrance Station
Distribution point to GH-MK
Distribution point to farthest GH-1AD(Audio line)
GH-VBC to farthest Monitor (Video line) 1 Monitor/Resid.
GH-VBC to farthest Monitor (Video line) 2 Monitors/Resid.
GH-VBC (STD) to GH-VBC (EXP)
GH-BC/VBC to each Power Supply
GH-NS to Power Supply
GH-MK to Power Supply
Accumulated total wiring, all stations
ENTRANCE STATION
#2 #1
GH-BC
GH-VBC
1P
1P
1P
1P
GH-BC
GH-VBC
#2 #1
1P
1P
1P 1P
1P
1P
1P
1P
1P (Audio)
1P (Video)
150m 150m
Expand pos.
max. 2
STDEXP
Standard pos.
STDEXP
GH-BC GH-VBC
GH-VBC
Direct-select call button Digital name scrolling
GH-VBC
*
Power Supply for GH-NS
*
Communication (talk and video) paths:
Przeglądanie stron 9
1 2 ... 5 6 7 8 9 10 11 12

Komentarze do niniejszej Instrukcji

Attilio Carmagnani 25 Sep 2024 | 11:03:54

?